mayuresh associates   accredited-calibration-laboratory
   

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

 
 

Elecrtotechnical Calibration
DC VOLTAGE
 
Temperature &
Mechanical Calibration
.........................................................
 
   Calibration

CALIBRATION: The set of operations which establish, under specified conditions, the relationship between values indicated by a measuring instrument..., and the corresponding known values of a measurand.  (from ISO Guide 25, 'definitions')
Our scope covers the calibration of :
Thermal Calibration
Range From -196°C to 1200 °C
List of instruments :
ASTM thermometers, Glass thermometers, Digital thermometers, Thermocouples (J,K,E,R,S,T,B), Thermistors, RTD PT100 sensors, PRTs, bimetal and industrial thermometers, Digital Hygrometers.
Incubator, Autoclave Sterlizers, Deep Freezer, Muffle Furnace, Hot air Oven, Fridge.
...................................................................................................................................................................................
Humidity Calibration
Range From 10 to 95% RH
List of instruments :
Digital Thermo hygrometers, Humidity Transmitters with/ without Indicators, Humidity chambers, Stability chambers.
...................................................................................................................................................................................
Electro technical Calibration  
Parameters calibrated :
DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Capacitance, Inductance, AC Resistance, Frequency, RPM, Time, Temperature Simulation.
List of Instruments :
Multimeters, Clampmeters, Decade Box, Panelmeter, Ammeter, Voltmeter, Stopwatch, Timer, High Voltage Tester, DC Power supply, Digital Calibrator, Function generator, Frequency counter, LCR meters, Capacitors, Inductors, Temperature Controller, Ohmmeter, Tachometer, RPM meter, pH meter, Conductivity meter.
...................................................................................................................................................................................
Mechanical Calibration
Paramaters calibrated :
Pressure (0 to 700 kg/sqcm)
Vacuum (-1 to 0 bar)
Mass (1mg to 200g)
Length (upto 600mm)
List of instruments :
Pressure Gauge, Vacuum Gauge, Pressure Transmitter, Vacuum Transmitter, Magnehelic Gauge, Analytical weighing balance, Vernier calliper, Micrometer, Height gauge
...................................................................................................................................................................................
Other Instruments: Luxmeter, Sound level meter, Air velocity meter